Your cart

Your cart is empty

Laguna Front Loading Gas Kilns

Laguna Front Loading Gas Kilns are professional grade gas kilns with a variety of sizes and configurations available.Sizes of these kilns range from 7.9 to over 54 cubic feet ! Learn more

Laguna Front Loading Gas Kilns are professional grade gas kilns with a variety of sizes and configurations available.Sizes of these kilns range from 7.9 to over 54 cubic feet ! Learn more

Laguna Gas Kiln Model Comparison

Laguna Clay Co. builds its LE-200 gas kilns in five standard sizes, from 9.2 to 40 cubic feet. Every model fires to cone 10 on natural gas or propane. Each kiln is built to order: you choose a brick or ceramic fiber lining and an updraft or downdraft design. The last number in each model name is its approximate inner volume in cubic feet.

Which Laguna gas kiln should I buy?

  • Your first gas kilnThe LE-200-9. At 9.2 cu ft it's Laguna's smallest standard size, a manageable step into cone 10 gas and reduction firing for one potter or a small studio.
  • Busy home or shared studiosThe LE-200-12 or LE-200-18. 12 or 18 cu ft holds glaze loads from several potters at once.
  • Schools and community studiosThe LE-200-18 or LE-200-24. Room for full class or member loads in a single firing.
  • Production and universitiesThe 40 cu ft LE-200-40, or the LE-200-40C car kiln, where you load the work on a car that rolls out of the kiln.
Model Inner volume Loading Fuel Draft Max temp Best for
LE-200-9 9.2 cu ft Front door Natural gas or propane Updraft or downdraft Cone 10 (2350°F) A first gas kiln for a potter or small studio
LE-200-12 12 cu ft Front door Natural gas or propane Updraft or downdraft Cone 10 (2350°F) Home and shared studios that fire often
LE-200-18 18 cu ft Front door Natural gas or propane Updraft or downdraft Cone 10 (2350°F) Schools and community studios
LE-200-24 23.9 cu ft Front door Natural gas or propane Updraft or downdraft Cone 10 (2350°F) Production potters and larger school programs
LE-200-40 40 cu ft Front door Natural gas or propane Updraft or downdraft Cone 10 (2350°F) High-volume production and universities
LE-200-40CCar kiln · Request quote 40 cu ft Roll-out car Natural gas or propane Updraft or downdraft Cone 10 (2350°F) Big or heavy loads set outside the kiln

Volumes are Laguna's published inner firing-chamber volumes. The 2350°F maximum firing temperature comes from Laguna's gas kiln manual. Laguna also builds custom sizes on request. Before you plan the gas line and hood, call us about the model and options you want: your plumber needs the kiln's BTU rating, and you need its outside dimensions.

Brick or fiber, updraft or downdraft

Brick kilns have a firebrick lining with 1½" fiber board backup insulation. Fiber kilns use ceramic fiber insulation with an ITC coating. Laguna says fiber saves up to 30% on yearly fuel costs, heats and cools faster, and has fewer wall-cracking problems than brick.

Updraft or downdraft: In an updraft kiln, the heat leaves through a flue in the top, with a slide damper above it. In a downdraft kiln, the heat travels down through the load and leaves through a flue in the floor.

Every model includes natural-draft, ceramic-tip venturi burners, direct-spark electronic ignition, a digital high-limit safety shut-off, manual burner valves and a water column gauge. A programmable controller (8 programs, 16 segments each) is optional. All Laguna gas kilns are ETL listed by Intertek.

Planning a gas kiln installation
  • Gas pressure: natural gas needs at least 6" water column at the kiln. Propane uses a two-stage regulator (about 5 PSI, then about 15" water column), and your propane supplier sizes the tank.
  • Gas line: a licensed plumber sizes it from the kiln's BTU rating, its distance from the meter and the number of elbows.
  • Clearance: at least 4 ft from combustible walls and 3 ft from noncombustible walls.
  • Venting: indoors, the kiln must be vented, usually with a hood (stainless steel is best). Outdoors, Laguna recommends a noncombustible roof 6 to 8 ft above the flue.
  • Permits and delivery: check with your local building department first. Kilns ship crated, and you'll need a forklift or pallet jack to unload one.

Not sure which model fits your needs? Call our kiln experts at (888) 774-2529.

Laguna Front Loading Gas Kilns

Laguna Gas kiln : shuttle car kilnLaguna Front Loading Gas Kilns are professional grade gas kilns with a variety of sizes and configurations available.
Sizes of these kilns range from 7.9 to over 54 cubic feet !

They can be configured for propane or natural gas. They can be made as standard front loading kilns or as shuttle car kilns. These kilns feature venturi burners with natural updraft air flow. They can be ordered in downdraft configuration as well.

Laguna Front-loading gas kilnChoose fiber or brick construction and upgrade to K26 brick for continuous high temp usage.

These Laguna commercial grade gas kilns are equally suited for schools, industry, or high output pottery studios.

Laguna Gas Kiln Standard Features:
  • Structural steel frame
  • 16 gauge steel skin (painted)
  • Heavy-duty, adjustable-hinge door (specify left or right mounted)
  • Gasketed, heat-lock door
  • K-26 firebrick floor
  • K-23 firebrick walls, arch and door (brick models only; K-26 optional)
  • 6", pre-compressed, high-purity, fiber panels (fiber models only)
  • High efficiency natural draft, ceramic-tip, venturi burners (specify natural gas or propane)
  • Heavy-duty burner manifold system
  • Direct-spark, electronic ignition system
  • Digital high-limit/safety shut-off controller
  • Manual burner control valves
  • Water column pressure gauge
  • Cordierite sight tube(s) with peephole plug(s)

Optional Features:

  • K-26 firebrick walls, arch and door - Recommended for Cone 10 firing
  • Programmable controller - 8 programs, 16 segments each (combinable)
  • Kiln shelving kits - Cordierite or silicon carbide
  • Wind apron (detachable)
  • Kiln hood - galvanized or stainless : Custom Made : Call for Quote

Note: Add $240 Crating Fee per kiln shipped.
Please allow 18-22 weeks for delivery.

Minimum Gas Pressure : 6" WC for Natural gas. 14" WC for propane.
High altitude operation may require smaller orifices or powered blowers